Welcome to the new look of TurboSquid. To switch to the Classic site, click the link in the Footer.

Phlips U/UTP Cat 6.max

All Extended Uses
Included Formats
3ds Max
3D Model Specifications
Product ID:462647
Published:
Geometry:Unknown
Polygons:0
Vertices:0
Textures:No
Materials:No
Rigged:No
Animated:No
UV Mapped:Yes
Unwrapped UVs:Unknown
Artist
TurboSquid Member Since September 2007
Currently sells 281 products
Achievements:
Unrated
Product Rating
Description
Phlips U-UTP Cat 6
Data installation cable

DIN: J-2YY

Application:
· Primary (Campus), Secondary (Riser) and Tertiary (Horizontal)
· IEEE 802.3 networks: 10Base-T, 100Base-T and 1000Base-T
· IEEE 802.5 16 MB networks: ISDN, TPDDI and ATM

Properties regarding fire performance:
· Self-extinguishing, in accordance with NEN-EN-IEC 60332-1

Remarks:
· Also available with a FRNC outer sheath, see under U/UTP Cat.6 mbzh (FRNC)
· A flexible version is available for application as patch-connection cable

Construction:
Conductor: solid plain copper
Insulation: polyethylene (PE)
Cores: 2 cores twisted to a pair
Assembly: pairs cabled together
Outer sheath: polyvinylchloride (PVC)

Electrical data::
Test voltage: 1 kV
LDC loop resistance: = 176 O/km
Resistance unbalance: = 2 %
Insulation resistance: = 2000 MO.km
Capacitance at 800 Hz: nom. 48 nF/km
Capacitance unbalance: = 1500 pF/km
Characteristic impedance: 100 ± 15 O (1 - 100 MHz)
       100 ± 22 O (100 - 250 MHz)
Velocity ratio: ± 67%
Propagation delay: = 535 ns/100 m
Delay skew: = 20 ns/100 m

Core colours:
Standard colours: white/blue and blue, white/orange and orange, white/green and green, white/brown and brown (in accordance with ISO/IEC 11801)

Standards/References:
EIA/TIA 568B
ISO/IEC 11801
NEN-IEC 61156-5
NEN-EN 50173
NEN-EN 50288-6-1

Additional information:
Minimum installation temperature: 0 °C
Operating temperature: min. -20 °C, max. +60 °C
Sheath colour: blue
Packaging: drums