EMC mbzh 0,6-1 kV 3x16 + afas16 mm2.max

All Extended Uses
Included Formats
3ds Max
Other Files
Koper Vlechtwerk Dicht.jpg
3D Model Specifications
Product ID:473899
Published:
Geometry:Unknown
Polygons:0
Vertices:0
Textures:No
Materials:No
Rigged:No
Animated:No
UV Mapped:Yes
Unwrapped UVs:Unknown
Artist
TurboSquid Member Since September 2007
Currently sells 281 products
Achievements:
Unrated
Product Rating
Description
EMC mbzh 0,6-1 kV 3x16 + afas16 mm2

VFD screened halogenfree installation cable

NEN: Z1S-YMz1Kafasmbzh 0,6/1kV rss

Application:
· Specially designed as a halogen free cable for feeding variable frequency driven (VFD) engines, for application on both primary and secundary engine side
· Also very suitable for feeding systems, which are susceptible to electromagnetic disturbances
· Can be applied in unfavourable conditions, like an increased ambient temperature, and in cable bundles
· Additional mechanical protection should be applied when laid in the ground

Properties regarding fire performance:
· Halogen free, in accordance with NEN-EN 50267 (IEC 60754)
· Low smoke, in accordance with NEN-EN-IEC 61034
· Flame retardant, in accordance with NEN-EN 50266-2-4 (IEC 60332-3-24 cat. C)
· Self-extinguishing, in accordance with NEN-EN-IEC 60332-1

General properties:
· Very good screening of electromagnetic disturbances to the surroundings
· The screening can also be used as protective earthing lead

Remarks:
· The copper wire braiding of the screen needs to be earthed in a gland. For this, special VFD-glands are available
· The copper foil is to be removed in the gland
· Earthing of the screen is done two-sided
· For the calculation of the conductor diameter the higher harmonics, caused by the variable frequency drives (VFD's), must be taken in to account. The temperature rise of the conductor can be higher than in case of sinusoidal currents
· The VFD cabinet should be very well earthed in accordance with the regulations of the manufacturer
· For cross-section of 35 mm² and above see HULTOFLEX-EMC MBZH

Construction:
Conductor: stranded plain annealed copper, round
Insulation: cross-linked polyethylene (XLPE)
Assembly: cores cabled together, filled to make a round shape
Inner sheath: halogen free flame retardant thermoplastic (LSOH)
Screening: copper foil over which a copper wire braid is applied
Outer sheath: halogen free flame retardant thermoplastic (LSOH)

Electrical data:
Voltage rating: 0,6/1 kV
Test voltage: 3,5 kV
Transfer Impedance: ? 100 m?/m at 100 MHz

Conductor colours:
3 cores: brown, black, grey

Standards/References:
KEMA 160
NEN-EN 50200
NEN-EN 50362
NEN-EN-IEC 60332-1
NEN-EN 50266
IEC 60332-3
NEN-EN-IEC 61034
NEN-EN 50267
IEC 60754

Additional information:
Minimum installation temperature: 0 °C
Maximum conductor temperature: 90 °C
       (temporary overload permissible until +130 °C)
Operating temperature: min. -40 °C, max. +80 °C
Sheath colour: grey
Approval: KEMA-KEUR, and approval by most important classification societies: American Bureau of Shipping, Bureau Veritas, Det Norske Veritas, Lloyds Register and Germanischer Lloyd
Packaging: drums

Related Products