elektrooke ALL-WEATHER SuperCAT UTP Cat5e
Data installation cable
Application:
· For direct burial
· Generic cabling systems
General properties:
· Good resistance to weather influences
· Good water-resistance
Remarks:
· For direct burial, cable must be laid at a depth of at least 0,5 metres
Construction:
Conductor: solid plain copper
Insulation: polyethylene (PE)
Cores: 2 cores twisted to a pair
Assembly: pairs cabled together, filled with waterproof gel
Outer sheath: polyethylene (PE) with a rip cord underneath
Electrical data:
Test voltage: 1 kV
LDC loop resistance: = 165 O/km
Resistance unbalance: = 2 %
Insulation resistance: = 2000 MO.km
Capacitance at 800 Hz: nom. 43 nF/km
Capacitance unbalance: = 1500 pF/km
Characteristic impedance: 100 ± 15 O (1 - 100 MHz)
100 ± 18 O (100 - 250 MHz)
Velocity ratio: ± 79%
Propagation delay: = 427 ns/100 m
Delay skew: = 12 ns/100 m
Transfer Impedance: at 1 MHz: == 15 mOhm/m
at 10 MHz: = 10 mO/m
at 30 MHz: = 30 mO/m
Core colours:
Standard colours: white/blue and blue, white/orange and orange, white/green and green, white/brown and brown (in accordance with ISO/IEC 11801
Standards/References:
EIA/TIA 568B
Additional information:
Minimum installation temperature: -40 °C
Operating temperature: min. -40 °C, max. +75 °C
Sheath colour: black